Shop

RUK Li-Ion Safety Box M

The Li-Ion Safety Box M is the larger box, 600 × 600 × 450 mm, for several tool batteries and compact power stations. Monitoring, power cut-off and suppression stay inside the closed system.

Li-Ion Safety Box M – Front view

A format that fits the workplace.

The square footprint of Box M belongs in the warehouse, production or a larger workshop, where several batteries charge at once. Inside there is room for tool packs side by side.

  • Automatic extinguishing systemIn critical conditions, the box independently releases extinguishing and cooling agents.
  • Monitored chargingCritical heat build-up is detected and the power supply is cut.
  • Pressure reliefIn the event of an incident, the pressure that builds up is released in a controlled way — the housing stays closed and the incident remains confined to the interior.
  • Multi-stage exhaust filtrationPollutants and toxic gases are reduced before leaving the system.
  • Safe charging insideFour interior sockets allow charging isolated from the working area.

Active fire protection

Fire protection box with automatic suppression

Monitored charging

Early detection before escalation

Exhaust filtration

Multi-stage gas reduction

Pressure relief

Controlled if an incident occurs

Certified safety

For professional use

Passive storage or an active safety system?

Charging several packs loose on the floor is not a system. The larger Box M holds tool batteries and a compact power station in one monitored chamber.

FeaturesStandard solutionsLi-Ion Safety Box M
Safe charging in a closed system✕✓
Early detection of critical temperatures✕✓
Acoustic warning in critical states✕✓
Automatic fire suppression✕✓
Multi-stage exhaust filtration✕✓
Active extinguishing and cooling system!✓
Pressure relief if an incident occurs!✓
Protection against a thermal chain reaction (thermal runaway)!✓
Controlled fire behaviour in a closed system✕✓
Limiting the spread of fire (when closed)!✓

Box M is compared with a passive cabinet that has no suppression. It too requires the closed state. The basis is the same TÜV NORD principle M 02-2022, not a blanket pass of every building code.

These are the reasons companies choose the Li-Ion Safety Box M/S

Protecting employees

On the larger chamber the alarm is for warehouse and production staff. Suppression starts while the door stays shut.

Protecting assets

Several batteries on one footprint are the larger fire load. Box M limits damage to goods, racking and the hall to the closed chamber.

Protecting operations

In the warehouse and in production, Box M gathers charging in one fixed place instead of leaving packs on trolleys and side surfaces.

A controlled safety environment

Box M watches the larger load of several batteries and keeps the reaction inside the square chamber.

Technical data of the Li-Ion Safety Box M

Box M, 600 × 600 × 450 mm, built for several tool batteries and compact power stations. The same active system in the larger format. Version 1.4 (04/2026).

Li-Ion Safety Box M at an angle: closed housing with control panel, temperature display, key switch and carrying handle
Product name
Li-Ion Safety Box M
Outer dimensions (L × W × H)
600 × 600 × 450 mm
Usable interior area
540 × 540 mm
Charging opening
500 × 230 mm (max. item height 200 mm)
Weight
43–45 kg (incl. extinguishing agent)
Color
Metallic Smoke Silver
Power supply
100–230 V AC | 50–60 Hz
Interior sockets
4 × 110/230 V
Total current
max. 10 A total
Internal power
13.6 V LiFePO4 (rechargeable)
Key switch
ON – box active / OFF – box inactive
Extinguishing agent
TRIDENT® foam agent, 12 l
Spray duration
approx. 4 min 30 s
Agent shelf life
10 years
Max. single battery
3.6 kWh
Max. total capacity
3.6 kWh
Protection class
IP54
Ambient temperature
5–45 °C
Humidity
5–95% RH
Maintenance
maintenance-free

Scope of delivery

  • 1× Li-Ion Safety Box M
  • 1× IEC power cable
  • 1× User manual
  • 1× Key

Note: Chargers are not included.

Warnings

  • Use exclusively for storing and charging lithium-ion batteries.
  • Full protective effect only when fully closed.
  • Do not store easily flammable materials in the immediate vicinity.
  • Only operate within the specified maximum battery capacities.
  • Ensure proper ventilation when used in poorly ventilated rooms.
Product datasheet PDF (DE)
TÜV NORD tested

TÜV-tested. Video-documented.

TÜV NORD Systems tested the larger Box M separately to the same principle M 02-2022. Those files are the Box M records, not the Box S ones.

Video: explosion test

Original footage of the TÜV explosion test of the Li-Ion Safety Box M.

Video: fire test

Original footage of the TÜV fire test including thermal imaging camera.

What companies say about the Li-Ion Safety Box M

On the production floor several device packs sit in Box M at once. The square plan takes the load without blocking the aisle.

Meyer Apps GmbH

A power station and the tool packs share Box M in our hall. Before that they stood in the open.

Paderheld GmbH

In the warehouse several tool batteries charge at once in Box M. Overnight that one chamber is the charging place, not the whole rack.

FuturEDU Labs UG

The larger lab benches charge their supplies closed inside Box M.

42 Apps UG

Looking for the right model for your application?